| Sign In | Join Free | My gimpguru.org |
|
Brand Name : inntronic
Model Number : ISP4MC3
Place of Origin : China
MOQ : 1pc
Payment Terms : L/C
Delivery Time : 15-30 days
Price : Negotiable
Type : Single Point Load Cell
Capacity : 0.3kg 0.5kg 2kg 3kg
Output : 2mv/v
Material : Aluminum
Application : electronic balance
Interchangeable brand : HBM
IP Protection standard : IP67
Accuracy grade : C3
Hysteresis error (dhy)3) : ±0.0150
Non-linearity (dlin)3) : ±0.0150
Small Size Low Capacity Load Cell Shielded Connection Cable For Electronic Balance
Good quality and long life
| − For determining small masses − Small size − Accuracy class C3 with OIML- R60 test report − Off center load compensated − Degree of protection IP65 according to IEC 529 − Shielded connection cable
|
| Type | IPW4MC3 | |||||||
| Order-No. | 1-PW4C3/300G-1 | 1-PW4C3/500G-1 | 1-PW4C3/2KG-1 | 1-PW4C3/3KG-1 | ||||
| Accuracy class1) | C3 | |||||||
| Number of load cell intervals (nLC) | 3000 | |||||||
| Maximum capacity (Emax)2)) | g/kg | 300 | 500 | 2 | 3 | |||
| Minimum LC verification interval (vmin) | g | 0.05 | 0.1 | 0.2 | 0.5 | |||
| Temperature effect on zero balance (TK0) | % v. Cn / 10 K
| 0.0233 | 0.0280 | 0.0140 | 0.0233 | |||
| Max. platform size | mm | 800 x 800 | ||||||
| Sensitivity (Cn) | mV/V | 1.0±0.1 | 2.0±0.2 | |||||
| Zero balance | 0±0.1 | |||||||
| Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K % of Cn | ±0.0175 ±0.0117 | ||||||
| Hysteresis error (dhy)3) | ±0.0150 | |||||||
| Non-linearity (dlin)3) | ±0.0150 | |||||||
| Minimum dead load output return (DR) |
Ω | ±0.0245 | ||||||
| Off center load error4) | ±0.0233 | |||||||
| Input resistance (RLC) | 380±38 | |||||||
| Output resistance (R0) | 380±38 | |||||||
| Reference excitation voltage (Uref) | V | 5 | ||||||
| Nominal range of excitation voltage (BU) | 15 | |||||||
| Insulation resistance (Ris) at 100 VDC |
GΩ | > 2 | ||||||
| Nominal temp. range (BT) | °C [°F] | −10 ... +40 [+14 ... +104] | ||||||
| Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | |||||||
| Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | |||||||
| load limit (EL ) at max. 100mm eccentricity | % of Emax % of Emax | 150 100 | ||||||
| Lateral load limit (Elq), static | 200 | |||||||
| Breaking load (Ed) | >300 | |||||||
| Deflection at Emax (snom), approx. | mm kg | < 0.4 | ||||||
| Weight (G), approx. | 0.07 | |||||||
| Protection class according to EN 60 529 (IEC 529) | IP67 | |||||||
| Material: Measuring element Coating Cable sheath | Aluminum Silicone rubber PVC | |||||||





|
|
Load Cell ISP4MC3 2kg C3 C4 Electronic Aluminum Single Point Weight force sensor For Electronic Balance scale 1.0±0.1mV/V Images |